POWERGuard Metered IP PDU

You can distribute energy with advanced technology POWERGuard Smart Group Socket Units, which have a user-friendly interface for monitoring and managing the energy consumption of your Data Center Cabinets and can be equipped with environmental monitoring sensors. You can professionally monitor your entire energy infrastructure with the advanced central management software that can be chosen optionally.

Wide Product Family

POWERGuard Total Current IP PDU products provide power distribution for your Data Center Cabinets and monitoring of total energy parameters on PDU basis. Our customer-oriented, high-tech smart PDU products can make reliable measurements with +/- 1% measurement accuracy and stable measurement values ​​up to 60 degrees Celcius. Environment monitoring sensor hub connection option, control module with high resolution large LCD display with “Hot Swap” feature and circuit breaker that can operate independently from temperature changes, can fully meet market needs.
.

+/- 1%
High energy measurement accuracy +/- 1%

Hot Swap
In case of malfunction, easily replaceable control unit, smart plug, service without disconnecting and power interruption

Color Graphic TFT LCD Display
Ability to see all kinds of parameters and messages with high resolution screen

Custom production C13-C19 and UK socket combinations
Special production possibility with different sockets and types

Locked C13 Sockets
Stable operation on PDU with external locking equipment

Circuit Breakers (Hydraulic Magnetic)
Circuit breaker function that is sensitive and not affected by temperature changes thanks to hydraulic magnetic circuit breakers.

Cascade 8 PDU
Cascade up to 8 PDUs to reduce network traffic and manage the system using less IP

Mobile device compatibility
Web interface compatible with mobile devices

Color Options
Black, blue and red color PDU options

Sensor Options
Support for up to 4 sensors allowing monitoring of environmental parameters such as temperature, humidity and water detection

Key Features

Vertical 0U, 56 × 56 (D x W) or horizontal 1U option IEC C13 safety adapter for IEC 60309 C14 cable connection
Thin profile feature IEC C13 panel socket connection safety with IEC C14 cord plug
Temperature independent circuit breakers Measuring on site with Ammeter Display (Optional)
Circuit breaker function that is sensitive and not affected by temperature changes thanks to hydraulic-magnetic circuit breakers With the integrated ammeter indicator, the current going to the devices can be measured.

MODEL

Inlet Metering

Outlet Metering

Breaker Metering

Branch Circuit Protection

Outlet Switching

IP

Basic PDU

Metered PDU

Outlet Metered PDU

Metered & Switched PDU

Outlet  Metered & Switched PDU

PDU Environment Sensors

2010 Temperature & Humidity Sensor

⦁ Real-time temperature & humidity monitoring sensor
⦁ Temperature measurement range: -25 C ° – 75 ℃
⦁ Temperature measurement tolerance: +/- 0.5 ℃
⦁ Temperature measurement resolution: 0.5 ℃
⦁ Humidity measuring range: 0% Rh – 90% Rh
⦁ Humidity measurement tolerance: +/- 4.5% Rh
⦁ Humidity measurement resolution: 0.1% Rh
⦁ Distance from main unit: 200m
⦁ Compatibility: SYSGuard 2001 & PDU

2020 Temperature Sensor

⦁ Temperature measurement range: -25 C ° – 75 ℃
⦁ Temperature measurement tolerance: +/- 0.5 ℃
⦁ Temperature measurement resolution: 0.5 ℃
⦁ Distance from main unit: 200m
⦁ Compatibility: SYSGuard 2001 & PDU

2030 Air Flow Sensor

⦁ Real-time airflow detection
⦁ Measures air flow near air ducts, door-window vents, air conditioning systems or ventilation
⦁ Distance from main unit: 200m
⦁ Compatibility: SYSGuard 2001 & PDU